HS7328 ANENG 626 Digital Multitester Rechargable
ANENG 626
Multitester 600V Voltage Test 6000 Counts Multimeter Portable Current Ohmmer Meter Rechargable USB Detector Tools
Technical indicators:
The instrument should be specified as a one-year cycle and recalibrated at 18°C to 28°C with a relative humidity of less than 75%.
Comprehensive indicators:
1) Automatically select the measurement function and range.
2) Full range overload protection.
3) The maximum allowable voltage between the measuring terminal and the earth: 1000V DC or 600V AC
4) Working height: up to 2000m
5) Display: VA
6) Maximum display value: 6000 numbers.
7) Polarity indication: automatic indication, "-" indicates negative polarity.
8) Overrange display: '0L' or '-0L'.
9) Sampling time: about 3 times/second
10) Unit display: with function, power unit display
11) Automatic shutdown time: 15 minutes
12) Power supply: 1000mA lithium battery
13)Temperature coefficient: less than 0.1X accuracy/ ℃
14) Working temperature: 0°C~40 °C
15) Storage temperature: -20°C~60°C
Specifications:
626 Information
|
Function
|
Range
|
Resolution
|
Accuracy
|
DC voltage
|
0.3mV~600V
|
0.01mV~0.1V
|
±(0.6%+5)
|
AC voltage
|
3mV~600V
|
0.01mV~0.1V
|
±(0.8%+5)
|
DC current
|
3mA~10A
|
0.1mA~0.01A
|
±(1.0%+8)
|
AC current
|
3mA~10A
|
0.1mA~0.01A
|
±(1.0%+8)
|
Resistance
|
0Ω~60MΩ
|
0.1Ω~0.01MΩ
|
±(0.8%+5)
|
Capacitor
|
0nF~20mF
|
0.001nF~0.01mF
|
±(2.5%+20)
|
Hz hertz
|
10Hz~7MHz
|
0.01Hz~0.01MHz
|
±(0.2%+5)
|
% Duty cycle
|
10%~90%
|
0.1
|
±(2.6%+7)
|
Temperature
°C°F
|
-40°C~1000°C
|
1°C
|
±(1.0%+3)
|
-40°F~1832°F
|
1°F
|
Naught Fire Wire
|
√
|
Flashlight lighting
|
√
|
NCV voltage induction
|
√
|
USB lithium
battery charging
|
√
|
On/Off
|
√
|
Battery type
|
3.7V 1000mA lithium battery
|
Diode
|
|
|
|